A Integrated Compressed Air Solution

The primary function of an air compression system is to compress atmospheric air to a higher pressure for use in various industrial and mechanical applications.
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)
Heating and cooling circulator (conventional type)

Heating and cooling circulator (conventional type)

Product Description:This equipment is driven by a circulating pump with a single circulating heat transfer medium, which passes through the heater and refrigeration heat exchanger to exchange heat and cold to reach the desired temperature. Closed piping design, high efficiency heat exchanger, reduce...
SHARE

Product Introduction
Product Display
Technical Parameter

Product Description:

This equipment is driven by a circulating pump with a single circulating heat transfer medium, which passes through the heater and refrigeration heat exchanger to exchange heat and cold to reach the desired temperature. Closed piping design, high efficiency heat exchanger, reduce the demand for heat transfer fluid at the same time, improve the heat utilization of the system, to achieve rapid temperature rise and fall. It is used to support other instruments and equipment that need to provide hot and cold sources, and is the ideal production equipment for modern fine chemistry, pharmaceuticals and biosynthesis of new materials.

Product advantages and features:

- Thermally conductive medium in a closed system with an expansion vessel, the expansion vessel in the heat conduction medium does not participate in the cycle, whether high or low temperature, expansion tank temperature of room temperature ~ 65 ℃, you can reduce the risk of heat conduction medium in the operation of the absorption of moisture and volatilization.

- Refrigeration can be started directly when the high temperature drops to the low temperature, continuously lifting and lowering the temperature, saving resources and improving work efficiency.

- The heat exchanger adopts fully brazed plate heat exchanger, which occupies little space and has high heat exchange efficiency.

- Circulation pump is high temperature resistant oil pump, with the advantages of high internal temperature, low noise and large flow rate.

- Over-temperature protection, leakage protection, phase sequence protection and other protective functions to improve the safety of the equipment.

- According to the user demand, can be customized water-cooled refrigeration system, explosion-proof models.


1-10L产品细节展示

20-100L产品细节展示


NameCooling   and heating circulators(-20℃)
model numberGDXH-5/-20+200GDXH-10/-20+200GDXH-20/-20+200GDXH-30/-20+200GDXH-50/-20+200GDXH-100/-20+200
Adaptable   device capacity1-5L5-10L10-20L10-30L10-50L50-100
Temperature feedbackDisplay   ModeLCD   digital display
Temperature range-20~160℃(No-load   temperature)-20~180℃(No-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature AccuracyPIDcontainment   ±1℃
Heating ModuleHeating   power2KW3KW4KW5KW6KW9KW
refrigeration unitCompressor   power935W885W1230W2340W2555W4540W
condensersFinned   condenser
refrigerantsR22
circulation pumpcyclic   power100W250W250W
recirculation flow20L/min(DN15pipe diameter)30L/min(DN20pipe diameter)
Maximum head6M12M
External Circulation Inlet and Outlet   DimensionsDN15
Security measuresTime   delay/leakage/overheating/overload/over-temperature protection
sizesOverall   Dimension500*550*780500*550*780780*605*1100820*640*1140860*640*11401105*815*1200
electric power sourcePower   Requirements220V/16A220V/50HZ(Air   switch: single-phase three-wire system,≥20A)220VAir   switch: single-phase three-wire system,≥25A)380V/50HZ(air   switch:TN-S,≥25A)380V/50HZ(air   switch:TN-S,≥40A)
NameCooling   and heating circulators(-30℃)
model numberGDXH-5/-30+200GDXH-10/-30+200GDXH-20/-30+200GDXH-30/-30+200GDXH-50/-30+200GDXH-100/-30+200
Adaptable   device capacity1-5L5-10L10-20L10-30L10-50L50-100L
Liquid   expansion volume8L10L13L20L
Temperature feedbackDisplay   ModeLCD   digital display
Temperature range-30~160℃(No-load   temperature)-30~180℃(No-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature AccuracyPIDcontainment±1℃
Heating ModuleHeating   power2KW3KW4KW5KW6KW9KW
refrigeration unitCompressor   power885W1230W1700W2580W2555W6000W
condensersFinned   condenser
refrigerantsR22
circulation pumpcyclic   power100W100W250W250W250W250W
recirculation flow20L/min(DN15pipe   diameter)30L/min(DN20pipe   diameter)
Maximum head6M12M
External Circulation Inlet and Outlet   DimensionsDN15
Security   measuresTime   delay/leakage/overheating/overload/over-temperature protection
sizesOverall   Dimension500*550*780500*550*780780*605*1100mm820*640*1140mm860*640*1140mm1105*815*1200mm
electric power sourcePower   Requirements220V/50HZ   16A One three-hole socket220V/50HZ(Air   switch: single-phase three-wire system,≥25A)380V/50HZ(air   switch:TN-S,≥25A)380V/50HZ(air   switch:TN-S,≥32A)380V/50HZ(air   switch:TN-S,≥40A)
NameCooling   and heating circulators(-40℃)
model numberGDXH-5/-40+200GDXH-10/-40+200GDXH-20/-40+200GDXH-30/-40+200GDXH-50/-40+200GDXH-100/-40+200
Adaptable   device capacity1-5L5-10L10-20L10-30L10-50L50-100L
Temperature feedbackDisplay   ModeLCD   digital display
highest temperature180℃200℃
Temperature range-40~160℃(No-load   temperature)-40~180℃(No-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature AccuracyPIDcontainment±1℃
Heating ModuleHeating   power2KW3KW4KW5KW6KW9KW
refrigeration unitCompressor   power1052W1500W2041W2700W3670W6450W
condensersFinned   condenser
refrigerantsR404A
circulation pumpcyclic   power100W250W
recirculation flow20L/min(DN15pipe   diameter)30L/min(DN20pipe   diameter)
Maximum head6M12M
External Circulation Inlet and Outlet   DimensionsDN15DN15DN15DN15DN15DN15
Security   measuresTime   delay/leakage/overheating/overload/over-temperature protection
sizesOverall   Dimension500*550*780mm500*550*850mm630*760*990mm640*770*1640mm760*990*1090mm810*1150*1210mm
electric power sourcePower   Requirements220V/50HZ   16AOne three-hole socket220V/50HZ(Air   switch:  single-phase three-wire   system,≥25A)220V/50HZ(Air   switch:  single-phase three-wire   system,≥32A)380V/50HZ(air   switch: TN-S,≥25A)380V/50HZ(air   switch: TN-S,≥32A)380V/50HZ(air   switch: TN-S,≥63A)
NameCooling   and heating circulators(-80℃)
model numberGDXH-5/-80+200GDXH-10/-80+200GDXH-20/-80+200GDXH-30/-80+200GDXH-50/-80+200GDXH-100/-80+200
Adaptable   device capacity1-5L5-10L10-20L10-30L10-50L50-100L
Temperature feedbackDisplay   ModeLCD   digital display
Temperature range-80~150℃(No-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature AccuracyPIDcontainment±1℃
Heating ModuleHeating   power2KW3KW4KW5KW6KW9KW
refrigeration unitCompressor   power1Level   1230W+2Level 1052W1Level   1700W+2Level 2041W1Level   2340W+2Level 2205W1Level   2555W+2Level 2970W1Level   5430W+2Level 4410W1Level   5430W+2Level 4410W
condensersFinned   condenser
refrigerantsR22/R23/混合R22/R23/hybridR404A
circulation pumpcyclic   power100W280W250W
recirculation flow12L/min(DN15pipe   diameter)30L/min(DN15pipe   diameter)30L/min(DN20pipe   diameter)
Maximum head6M10M12M
External Circulation Inlet and Outlet   DimensionsDN15
Security   measuresTime   delay/leakage/overheating/overload/over-temperature protection
sizesOverall   Dimension520*650*1000mm520*650*1000mm710*1000*1220mm960*760*1205mm1220*800*1250mm810*1150*1210mm
electric power sourcePower   Requirements220V(Air   switch:  single-phase three-wire   system,≥25A)220V/50HZ(Air   switch:  single-phase three-wire   system,≥40A)380V/50HZ(air   switch: TN-S,≥25A)380V/50HZair   switch: TN-S,≥32A)380V/50HZ(air   switch: TN-S,≥40A)380V/50HZ(air   switch: TN-S,≥63A)
NameCooling   and heating circulators(-120℃)
model numberGDXH-50/-120+100GDXH-100/-120+100
Adaptable   device capacity10-50L50-100L
Temperature feedbackDisplay   ModeLCD   digital display
Temperature range-100~100℃(No-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature AccuracyPIDcontainment±1℃
Heating ModuleHeating   power6KW9KW
refrigeration unitCompressor   power1Level   5430W+2Level 4410W+3Level 4410W1Level   7400W+2Level 5880W+3Level 5880W
condensersFinned   condenser
refrigerantsR22/R23/R14/hybrid
circulation pumpcyclic   power370W
maximum flow30L/min(DN15pipe diameter)
Rated head20M
External Circulation Inlet and Outlet   DimensionsDN15
Security   measuresTime   delay/leakage/overheating/overload/over-temperature protection
Power   Requirements380V/50HZ(Air   switch, 3-Phase 5-Wire ≥63A)