EN

banner

Products

A Integrated Compressed Air Solution

The primary function of an air compression system is to compress atmospheric air to a higher pressure for use in various industrial and mechanical applications.
Refrigeration and heating cycle generator (program control type)
Refrigeration and heating cycle generator (program control type)
Refrigeration and heating cycle generator (program control type)
Refrigeration and heating cycle generator (program control type)
Refrigeration and heating cycle generator (program control type)
Refrigeration and heating cycle generator (program control type)
Refrigeration and heating cycle generator (program control type)
Refrigeration and heating cycle generator (program control type)

Refrigeration and heating cycle generator (program control type)

Product Description:This equipment is driven by a circulating pump with a single circulating heat transfer medium, which passes through the heater and refrigeration heat exchanger to exchange heat and cold to reach the desired temperature. Closed piping design, high efficiency heat exchanger, reduce...
SHARE

Product Introduction
Product Display
Technical Parameter

Product Description:

This equipment is driven by a circulating pump with a single circulating heat transfer medium, which passes through the heater and refrigeration heat exchanger to exchange heat and cold to reach the desired temperature. Closed piping design, high efficiency heat exchanger, reduce the demand for heat transfer fluid at the same time, improve the heat utilization of the system, to achieve rapid temperature rise and fall. It is used to support other instruments and equipment that need to provide hot and cold sources, and is the ideal production equipment for modern fine chemistry, pharmaceuticals and biosynthesis of new materials.

Product advantages and features:

- Thermally conductive medium in a closed system with an expansion vessel, the expansion vessel in the heat conduction medium does not participate in the cycle, whether high or low temperature, expansion tank temperature of room temperature ~ 65 ℃, you can reduce the risk of heat conduction medium in the operation of the absorption of moisture and volatilization.

- Refrigeration can be started directly when the high temperature drops to the low temperature, continuously lifting and lowering the temperature, saving resources and improving work efficiency.

- The heat exchanger adopts fully brazed plate heat exchanger, which occupies little space and has high heat exchange efficiency.

- Circulation pump is high temperature resistant oil pump, with the advantages of high internal temperature, low noise and large flow rate.

- Over-temperature protection, leakage protection, phase sequence protection and other protective functions to improve the safety of the equipment.

- According to the user demand, can be customized water-cooled refrigeration system, explosion-proof models.


产品细节展示

NameRefrigeration   and heating cycle machine (-20 degrees)
ModelGDXH-5/-20+200GDXH-10/-20+200GDXH-20/-20+200GDXH-30/-20+200GDXH-50/-20+200GDXH-100/-20+200
Adaptable device capacity1-5L5-10L10-20L10-30L10-50L50-100
Liquid expansion volume8L8L10L10L13L20L
Working conditionsOptimum   ambient temperature≤30℃
Optimum relative humidity≤60%
Temperature feedbackDisplay   ModeLCD   digital display
Maximum temperature180℃200℃
Operating temperature range-20~160℃(no-load   temperature)-20~180℃(no-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature accuracyPID   control ±1℃
Heating moduleHeating   power2KW3KW4KW5KW6KW9KW
Refrigeration UnitCompressor   power935W885W1230W2340W2580W4540W
Rated cooling capacity2805W2770W3835W7200W8150W14500W
CondenserFinned   condenserFinned   condenserFinned   condenserFinned   condenserFinned   condenserFinned   condenser
refrigerantR22
Circulation pumpCycle   Power100W250W250W
Circulation flow20L/min   (DN15 pipe diameter)30L/min   (DN20 pipe diameter)
Maximum lift6M12M
External circulation inlet and outlet dimensionsDN15
Safety measuresDelay/leakage/overheating/overtemperature   protection
AccessoriesCirculation   pipe4-point   stainless steel insulation pipe 1*1.5m 1*2m
Liquid outlet valveDN15   ball valve
Dimensions/weightOverall   dimensions500*550*780500*550*780780*605*1100820*640*1140860*640*11401105*815*1200
Net weight/gross weight110kg120/140126/146144/170164/192215/265
power supplyRated   total power3365W4225W5660W7770W9010W14290W
Power Requirements220V/16A220V/50HZ   (Air switch: single-phase three-wire, ≥20A)220V   (Air switch: single-phase three-wire, ≥25A)380V/50HZ   (Air switch: three-phase five-wire system, ≥25A)380V/50HZ   (Air switch: three-phase five-wire system, ≥40A)
nameRefrigeration   and heating cycle machine (-30 degrees)
modelGDXH-5/-30+200GDXH-10/-30+200GDXH-20/-30+200GDXH-30/-30+200GDXH-50/-30+200GDXH-100/-30+200
Adaptable device capacity1-5L5-10L10-20L10-30L10-50L50-100L
Liquid expansion volume8L10L13L20L

Optimum   ambient temperature≤25℃
Working conditionsOptimum   relative humidity≤60%
Temperature feedbackDisplay   ModeLCD   digital display
Maximum temperature180℃180℃200℃200℃200℃200℃
Operating temperature range-30~160℃(no-load   temperature)-30~180℃(no-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature accuracyPID   control ±1℃
Heating moduleHeating   power2KW3KW4KW5KW6KW9KW
Refrigeration UnitCompressor   power885W1230W1700W2580W2555W6000W
Rated cooling capacity2770W3835W5375W8150W8150W19200W
CondenserFinned   condenser
refrigerantR22
Circulation pumpCycle   Power100W100W250W250W250W250W
Circulation flow20L/min   (DN15 pipe diameter)30L/min   (DN20 pipe diameter)
Maximum lift6M12M
External circulation inlet and outlet   dimensionsDN15
Safety measuresDelay/leakage/overheating/overtemperature   protection
AccessoriesCirculation   pipe4-point   stainless steel insulation pipe 1*1.5m 1*2m
Liquid outlet valveDN15   ball valve
Dimensions/weightOverall   dimensions500*550*780500*550*780780*605*1100mm820*640*1140mm860*640*1140mm1105*815*1200mm
Net weight/gross weight110kg/120kg/140kg126kg/146kg144kg/170kg164kg/192kg215kg/265kg
power supplyRated   total power3315W4660W6100W8010W8985W15750W
Power Requirements220V/50HZ   16A three-hole socket220V/50HZ   (Air switch: single-phase three-wire, ≥25A)380V/50HZ   (Air switch: three-phase five-wire system, ≥25A)380V/50HZ   (Air switch: three-phase five-wire system, ≥32A)380V/50HZ   (Air switch: three-phase five-wire system, ≥40A)
nameRefrigeration   and heating cycle machine (-40 degrees)
modelGDXH-5/-40+200GDXH-10/-40+200GDXH-20/-40+200GDXH-30/-40+200GDXH-50/-40+200GDXH-100/-40+200
Adaptable device capacity1-5L5-10L10-20L10-30L10-50L50-100L
Liquid expansion volume10L12L15L

Optimum   ambient temperature≤25℃
Working conditionsOptimum   relative humidity≤60%
Temperature feedbackDisplay   ModeLCD   digital display
Maximum temperature180℃200℃
Operating temperature range-40~160℃(no-load   temperature)-40~180℃(no-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature accuracyPID   control ±1℃
Heating moduleHeating   power2KW3KW4KW5KW6KW9KW
Refrigeration UnitCompressor   power1052W1500W2041W2700W3670W6450W
Rated cooling capacity2921W4350W6900W7850W5300W9350W
CondenserFinned   condenser
refrigerantR404A
Circulation pumpCycle   Power100W250W
Circulation flow20L/min   (DN15 pipe diameter)30L/min   (DN20 pipe diameter)
Maximum lift6M12M
External circulation inlet and outlet   dimensionsDN15DN15DN15DN15DN15DN15
Safety measuresDelay/leakage/overheat/overload/overtemperature   protection
AccessoriesCirculation   pipe4-point   stainless steel insulation pipe 1*1.5m 1*2m
Liquid outlet valveDN15   ball valve
Dimensions/weightOverall   dimensions500*550*780mm500*550*850mm630*760*990mm640*770*1640mm760*990*1090mm810*1150*1210mm
Net weight/gross weight
120kg/?kg126kg/146kg144kg/170kg190kg/220kg215kg/265kg
power supplyRated   total power3400W4750W6400W8200W10100W16060W
Power Requirements220V/50HZ   16A three-hole socket220V/50HZ   (Air switch: single-phase three-wire, ≥25A)220V/50HZ   (Air switch: single-phase three-wire, ≥32A)380V/50HZ   (Air switch: three-phase five-wire system, ≥25A)380V/50HZ   (Air switch: three-phase five-wire system, ≥32A)380V/50HZ   (Air switch: three-phase five-wire system, ≥63A)
NameRefrigeration   and heating cycle machine (-80 degrees)
ModelGDXH-5/-80+200GDXH-10/-80+200GDXH-20/-80+200GDXH-30/-80+200GDXH-50/-80+200GDXH-100/-40+200
Adaptable device capacity1-5L5-10L10-20L10-30L10-50L50-100L
Liquid expansion volume8L10L12L15L

Optimum   ambient temperature≤30℃≤25℃
Working conditionsOptimum   relative humidity≤60%≤60%≤60%≤60%≤60%≤60%
Temperature feedbackDisplay   ModeLCD   digital display
Maximum temperatureDue   to the limitation of heat transfer medium, the maximum heating temperature is   160℃200℃
Operating temperature range-80~150℃(no-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature accuracyPID   control ±1℃
Heating moduleHeating   power2KW3KW4KW5KW6KW9KW
Refrigeration UnitcompressorRotary   compressorRotary   compressorRotary   compressor/piston compressorRotary   compressorScroll   compressor/piston compressor
Compressor powerLevel   1 1230W + Level 2 1052WLevel   1 1700W + Level 2 2041WLevel   1 2340W + Level 2 2205WLevel   1 2555W + Level 2 2970WLevel   1 5430W + Level 2 4410W6450W
CondenserFinned   condenser
refrigerantR22/R23/MixedR22/R23/MixedR404A
Circulation pumpCycle   Power100W280W250W
Circulation flow12L/min   (DN15 pipe diameter)30L/min30L/min   (DN20 pipe diameter)
Maximum lift6M10M12M
External circulation inlet and outlet   dimensionsDN15
Safety measuresDelay/leakage/overheat/overload/overtemperature   protection
AccessoriesCirculation   pipe4-point   stainless steel insulation pipe 1*1.5m 1*2m
Liquid outlet valveDN15DN15   ball valve
Dimensions/weightOverall   dimensions520*650*1000mm520*650*1000mm
960*760*1205mm1220*800*1250mm810*1150*1210mm
Net weight/gross weight




215kg/265kg
power supplyRated   total power4600W7200W9325W11300W16680W16060W
Power Requirements220V   (Air switch: single-phase three-wire, ≥25A)220V/50HZ   (Air switch: single-phase three-wire, ≥40A)380V/50HZ   (Air switch: three-phase five-wire system, ≥25A)380V/50HZ   (Air switch: three-phase five-wire system, ≥32A)380V/50HZ   (Air switch: three-phase five-wire system, ≥40A)380V/50HZ   (Air switch: three-phase five-wire system, ≥63A)
NameRefrigeration   and heating cycle machine - 120℃
ModelGDXH-50/-120+100GDXH-100/-120+100
Adaptable device capacity10-50L50-100L
Liquid expansion volume30L

Optimum   ambient temperature≤30℃
Working conditionsOptimum   relative humidity≤60%
Temperature feedbackDisplay   ModeLCD   digital display
Maximum temperatureDue   to the limitation of heat transfer medium, the maximum heating temperature is   120℃
Operating temperature range-100~100℃(no-load   temperature)
Temperature displayCirculation   system temperature (outlet temperature)
Temperature accuracyPID   control ±1℃
Heating moduleHeating   power6KW9KW
Refrigeration UnitCompressorScroll   compressor/piston compressor
Compressor powerLevel   1 5430W + Level 2 4410W + Level 3 4410WLevel   1 7400W + Level 2 5880W + Level 3 5880W
CondenserFinned   condenser
refrigerantR22/R23/R14/Mixed
Circulation pumpCycle   Power370W
Maximum flow30L/min   (DN15 pipe diameter)
Rated head20   meters
External circulation inlet and outlet   dimensionsDN15
Safety measuresDelay/leakage/overheat/overload/overtemperature   protection
AccessoriesCirculation   pipe4-point   stainless steel insulation pipe 1*1.5m 1*2m4-point   stainless steel insulation pipe 1*1.5m 1*2m
Liquid outlet valveDN15
Dimensions/weightOverall   dimensions

Net weight/gross weight

power supplyRated   total power22100W31000W
Power Requirements380V/50HZ   (Air switch: three-phase five-wire system, ≥63A)


Free Consultation

Please feel free to contact us, we will reply you within 24 hours.

Format: +86 123 4567 8901
⟳ Refresh Code
All fields marked with * are required